AQUA – Rain Chambers Designed for the simulation of Rain/Water Spray as per IEC-60529, IS-9000 Part XVI-1983 and JIS-D 0203-1976 with features like fully Non-corrosive interior and exterior. Characteristic water flow patterns as per IPX1 – IPX4 and R1, R2, S1 & S2 standards. AQUA – Design and Construction
Exterior with non-corrosive FRP (Fiber Reinforced Plastic).
Interior with non-corrosive FRP (Fiber Reinforced Plastic) / stainless steel.
Large capacity (100 Ltrs) water reservoir with automatic water refilling facility.
Rotating test table to expose the specimen for spray from all sides.
Rotating spray and rain nozzle arms are designed for JIS specification.
The chamber is also designed for multiple tests as per different standards
Designed for re-circulation of water for continuous tests.
Required pressure regulators, flow meters & guages for pressure and flow control of sprays.
Models Available
Model No
Chamber Size
Test standard Compliance
AQUA-1000-IXX
1000L (1000W x 1000D x 1000H) mm
IEC-60529. Tests IPX1 – IPX4
AQUA-3500-IXX
3500L (1500W x 1500D x 1500H) mm
AQUA-8000-IXX
8000L (2000W x 2000D x 2000H) mm
AQUA-1000-XJX
1000L (1000W x 1000D x 1000H) mm
JIS-D 0203-1976 as per R1, R2, S1 & S2
AQUA-3500-XJX
3500L (1500W x 1500D x 1500H) mm
AQUA-8000-XJX
8000L (2000W x 2000D x 2000H) mm
AQUA-1000-XXB
1000L (1000W x 1000D x 1000H) mm
IS-9000 Part XVI-1983
AQUA-3500-XXB
3500L (1500W x 1500D x 1500H) mm
AQUA-8000-XXB
8000L (2000W x 2000D x 2000H) mm
AQUA-1000-IJX
1000L (1000W x 1000D x 1000H) mm
IEC-60529. Tests IPX1 – IPX4JIS-D 0203-1976 as per R1, R2, S1 & S2